SuditekPurity Spec pack

03 — Series / WASH

WASH — along a wall or a line

The channel is sized to the run, not the run to the channel. On a refit that usually means a shorter basket and a deeper body.

WASH — fixed parameters

Route
grating → basket → seal → outlet
Body
304 / 316
Grate
bar / mesh / slot
Basket
full length, by hand
Seal
50 mm, removable
Length
on request

Section

W GRATE BASKET SEAL
SEC 03-01 · WASH channel · NTSSHEET 06

A channel that follows the wall at the wet end of the room, takes the water off the whole run, and gives the whole length a basket you can lift in one piece. Flow is spread over the length, so the outlet sees less at once than a point drain does.

How this series fails

  • A basket made in sections that have to be lifted one by one — they get lifted once, then never.
  • An outlet at the low end only, with the fall running the other way: the far end silts up.
  • A slot grate over a wide body: the gap is what a squeegee pushes into, not out of.

What decides the size

  • Run length and the fall available across it
  • Solids: a slot grate is a decision about what you are willing to hand-pick
  • Whether a pallet truck or racking crosses it — that decides the rail
  • Who lifts the basket, and whether they can lift the full length alone

Structure only — not published

  • Dimensions: length, width, depth, outlet position and build-up height — issued on the dimension sheet per project
  • Load class for each grate variant, once tested
  • Assembly photographs, once the shoot is done
  • A worked example with a run length, a fall and an outlet, as a downloadable section